Downed overhead wires, power outages, and generators

Three rules for fallen power lines, deadly electrical myths, and safe generator operation.

Nor’easters, winter ice storms, and summer wind gusts frequently bring heavy trees down across Columbia County’s rural utility lines. Low or downed wires can be fatal even at long distances.

Three rules for fallen overhead wires

  1. Rule #1 — Treat all wires as high-voltage and energized: Even telephone, cable, and fiber data wires can carry a lethal electrical charge if they are touching high-voltage primary lines further down the road beyond your line of sight.
  2. Rule #2 — Stay at least one full pole-span away: Even soil and wet pavement conduct electricity. Stay at least one complete utility pole span away in all directions from a broken wire, and warn others to stay back.
  3. Rule #3 — Call 911 immediately: 911 will dispatch Ghent firefighters and law enforcement to secure the scene first, and notify the utility company’s emergency line crew.

Dangerous myths vs. facts about downed power lines

  • MYTH: “Tires are electrical insulators.” FACT: Tires are electrical conductors, not insulators. You are safe inside your car when a live wire falls on it only because the metal vehicle body forms a path around you through the tires into the ground. Stay inside your vehicle until NYSEG or National Grid shuts off the power. If a vehicle fire forces you to evacuate, jump completely clear with both feet together so you never touch the vehicle and the ground at the same time.
  • MYTH: “Power lines are insulated.” **FACT:**Roughly 90% of outdoor overhead power lines are not insulated, and weather-coatings on the remaining 10% degrade over time. No overhead line is ever safe to touch.
  • MYTH: “Only high voltage is dangerous.” FACT: Voltage is the pressure, but amperage (amps) is what kills. It takes less than one-quarter of one amp to put a human heart into fatal ventricular fibrillation — while a typical home service carries 100 to 200 amps.
  • MYTH: “When a wire falls to the ground, it automatically shuts off.” FACT: Utility breakers trip only when they detect a massive sudden short circuit. A wire resting on dry soil, asphalt, or a tree often does not draw enough current to trip the breaker and remains fully energized.
  • MYTH: “A live wire always sparks or hums.” FACT: A wire sparks only when making loose, intermittent contact. Once it rests firmly on the ground, it often makes zero noise and zero sparks while remaining lethal.
  • MYTH: “Wood and household rubber boots/gloves insulate you.” FACT: Damp wood conducts electricity readily, and household rubber gloves or shoe soles contain durability additives that make them electrical conductors. Only utility-grade 100% pure tested rubber insulates against line voltage.

Portable generator safety

  • Never run a generator indoors, in a basement, or inside a garage, even with the garage door open. Carbon monoxide (CO) can reach lethal concentrations in minutes.
  • Place generators outdoors at least 20 feet away from any window, door, or vent, with exhaust pointed away from the home.
  • Never plug a generator into a wall outlet (“backfeeding”). Backfeeding sends lethal step-up voltage back onto utility lines, endangering line workers and firefighters.
  • Let the generator cool for 15 minutes before refueling.